Universidad San Sebastián  
 

Repositorio Institucional Universidad San Sebastián

Búsqueda avanzada

Descubre información por...

 

Título

Ver títulos
 

Autor

Ver autores
 

Tipo

Ver tipos
 

Materia

Ver materias

Buscar documentos por...




Mostrar el registro sencillo del ítem

dc.contributor.author Arroyo Jofre, Patricio Alejandro
dc.contributor.author Ulloa, David L.
dc.contributor.author Andrades Ramirez, Oscar
dc.contributor.author Alfaro, Bryan
dc.contributor.author Castillo-Paredes, Antonio
dc.contributor.author Chirosa Ríos, Luis
dc.date.accessioned 2024-09-12T03:46:24Z
dc.date.available 2024-09-12T03:46:24Z
dc.date.issued 2024-07
dc.identifier.issn 2075-4663
dc.identifier.other Mendeley: 161aa96c-faa8-3226-87ec-bf5f50b4c27c
dc.identifier.uri https://repositorio.uss.cl/handle/uss/11858
dc.description Publisher Copyright: © 2024 by the authors.
dc.description.abstract The purpose of the study was to analyze the test–retest reliability of an isometric and isometric/vibratory muscular strength protocol in the bilateral seated bench press (BSBP), bilateral seated rowing (BSR), unilateral seated right knee extension (USKER), and left knee extension (USKEL) tests controlled using functional electromechanical dynamometry (FEMD) in healthy young adults. A repeated measures design was used to determine the reliability of a muscular strength protocol in isometric and isometric vibration modes with FEMD. No significant differences were found in test–retest analysis (p > 0.05; ES < 0.20); and high reliability (CV = 4.65–5.02%; ICC = 0.99–0.98) was found for BSBP measures, and acceptable reliability (CV = 3.71–9.61%; ICC = 0.98–0.95) was found for BSR, USKER, and USKEL. Furthermore, the coefficients between the two measures were strong (r = 0.963–0.839) and highly significant (p = 0.001) for maximal strength in the isometric and maximal isometric/vibratory assessment of muscle strength in all muscle strength tests. This study demonstrates that isometric and maximal isometric/vibratory strength in the BSBP, BSR, USKER, and USKEL tests can be measured with high reliability and reproducibility using the FEMD. en
dc.language.iso eng
dc.relation.ispartof vol. 12 Issue: no. 7 Pages: 175
dc.source Sports
dc.title Test–Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry : test y retest de un protocolo de fuerza muscular isométrica e isométrica/vibratoria con dinamometría electromecánica funcional en
dc.type Artículo
dc.identifier.doi 10.3390/sports12070175
dc.publisher.department Facultad de Educación
dc.publisher.department Facultad de Ciencias de la Educación


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar


Listar

Mi cuenta