Universidad San Sebastián  
 

Repositorio Institucional Universidad San Sebastián

Búsqueda avanzada

Descubre información por...

 

Título

Ver títulos
 

Autor

Ver autores
 

Tipo

Ver tipos
 

Materia

Ver materias

Buscar documentos por...




Mostrar el registro sencillo del ítem

dc.contributor.author Palacio, Daniel A.
dc.contributor.author Oñate, Pablo
dc.contributor.author Esquivel, Samir
dc.contributor.author Meléndrez, Manuel
dc.contributor.author Pereira, Eduardo
dc.contributor.author Rivas, Bernabé L.
dc.date.accessioned 2024-09-26T00:49:55Z
dc.date.available 2024-09-26T00:49:55Z
dc.date.issued 2023-10
dc.identifier.issn 2077-0375
dc.identifier.uri https://repositorio.uss.cl/handle/uss/13712
dc.description Publisher Copyright: © 2023 by the authors.
dc.description.abstract The presence of antibiotics in aquatic systems in recent years has become a global environmental and public health concern due to the appearance of strains resistant to these antibiotics. Oxytetracycline (OXT) is a high-impact antibiotic used for both human and veterinary consumption, and it is the second most used antibiotic in aquaculture in Chile. Based on the above, this problem is addressed using a linear polymer whose structure is composed of aromatic rings and quaternary ammonium groups, which will help enhance the removal capacity of this antibiotic. To obtain the polycation, a radical polymerization synthesis was carried out using (4-vinylbenzyl)-trimethylammonium chloride as the monomer. The polycation was characterized via Fourier Transform Infrared spectroscopy (FTIR) and Nuclear Magnetic Resonance (NMR). The removal studies were conducted under different experimental conditions such as pH levels (3.0, 5.0, 7.0, 8.0, and 11.0), ionic strength (0.0–0.50 mg L−1 of NaCl), polymer dose (0.25–25.5 mg), variation of the antibiotic concentration (1–100 mg L−1), and evaluation of the maximum retention capacity, as well as load and discharge studies. The antibiotic retention removal was higher than 80.0%. The antibiotic removal performance is greatly affected by the effect of pH, ionic strength, molar ratio, and/or OXT concentration, as these parameters directly affect the electrostatic interactions between the polymer and the antibiotics. The diafiltration technique was shown to be highly efficient for the removal of OXT, with maximum removal capacities of 1273, 966, and 778 mg OXT g−1 polycation. In conclusion, it can be said that coupling water-soluble polymers to the diafiltration technique is an excellent low-cost way to address the problem of antibiotics in aquatic systems. en
dc.language.iso eng
dc.relation.ispartof vol. 13 Issue: no. 10 Pages:
dc.source Membranes
dc.title Study of the Efficiency of a Polycation Using the Diafiltration Technique in the Removal of the Antibiotic Oxytetracycline Used in Aquaculture en
dc.type Artículo
dc.identifier.doi 10.3390/membranes13100828


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem