Universidad San Sebastián  
 

Repositorio Institucional Universidad San Sebastián

Búsqueda avanzada

Descubre información por...

 

Título

Ver títulos
 

Autor

Ver autores
 

Tipo

Ver tipos
 

Materia

Ver materias

Buscar documentos por...




Mostrar el registro sencillo del ítem

dc.contributor.author Gallardo, Hugo Tapia
dc.contributor.author Del Sol, Mariano
dc.contributor.author González, Paul Medina
dc.contributor.author Escobar-Cabello, Máximo
dc.contributor.author Muñoz-Cofré, Rodrigo
dc.contributor.author Jerez-Mayorga, Daniel
dc.contributor.author Lizama-Pérez, Rodrigo
dc.date.accessioned 2024-09-26T00:50:06Z
dc.date.available 2024-09-26T00:50:06Z
dc.date.issued 2023-12-01
dc.identifier.issn 0717-9367
dc.identifier.uri https://repositorio.uss.cl/handle/uss/13726
dc.description Publisher Copyright: © 2023, Universidad de la Frontera. All rights reserved.
dc.description.abstract Skeletal muscle can be assessed in a number of different ways. Consequently, ultrasound evaluation has become a relevant diagnostic tool. This procedure allows measuring muscle thickness (MT) and pennation angle (PA). Furthermore, during the initial training of physical therapists it is important in a diagnostic procedure, to exercise reliability in measurement in comparison to the expert. Therefore, the objective of this study is to determine the inter-rater reliability in the measurement of MT and PA, through ultrasound evaluation, between an expert and a physical therapist in training. This training was comprised of three phases: The theoretical cycle, the practical cycle and the reliability process. For the latter, ten different tests were performed for each of the MT 1, MT 2 and MT 3 and PA measurements. Inter-rater reliability in the MT measurement was good to excellent in the three attempts MT1 (ICC=0.81; p=0.001), MT2 (ICC=0.86; p<0.001), MT3 (ICC=0. 88;<0.001). On the other hand, reliability of the PA was poor to fair (ICC=0.21; p=0.143. In conclusion, this research indicates that there is excellent inter-rater reliability in the measurement of MT. This does not however apply to the measurement of PA. It is therefore suggested that practical hours during the learning process of this measure be increased. en
dc.language.iso spa
dc.relation.ispartof vol. 41 Issue: no. 6 Pages: 1846-1851
dc.source International Journal of Morphology
dc.title Confiabilidad Inter-evaluador en la Medición del Grosor Muscular y el Ángulo de Penación a través de la Evaluación Ecográfica : Estudio entre un Experto y un Kinesiólogo en Formación es
dc.title.alternative Inter-Evaluator Reliability in Measurement of Muscle Thickness and Penance Angle through Ultrasound EvaluationComparison Study between an Expert and a Physical Therapist in Training en
dc.type Artículo
dc.identifier.doi 10.4067/S0717-95022023000601846
dc.publisher.department Facultad de Medicina y Ciencia


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem